Breaking load and working load
Breaking load (MBL) is the force at which a rope, wire rope or net twine breaks in the specified test. Working load (WLL) is the load you may actually apply in use. It is always well below the breaking load, normally the breaking load divided by a design factor.
The two figures are always read together. For fibre rope and wire rope, the working load is generally the breaking load divided by the design factor of the application. For cut-to-length rope without a WLL, Hamburger Tauwerk recommends at most one fifth of the breaking load (factor 5). For nets, the system rating of the finished net applies, not the breaking load of a single mesh. For hybrid ropes, the figure for the finished rope applies, not the sum of the material breaking loads.
Working load and working stretch are different quantities: the working load is a force, the working stretch is an elongation. The catalogue breaking load is generally the linear test value on new rope and does not yet describe the load of the finished end termination.
- Last reviewed
- · Hamburger Tauwerk Fabrik · Review cycle: semi-annual
Breaking load and working load: key facts
- In brief
- Working load = breaking load divided by the application-specific design factor, where the manufacturer or standard specifies this
- Also known as
- Breaking load, Minimum Breaking Load (MBL), nominal breaking load, minimum breaking force, breaking strength (German: Bruchlast, Mindestbruchkraft); working load, Working Load Limit (WLL), SWL, payload, load capacity (German: Arbeitslast, Nutzlast, Tragfähigkeit)
- Field
- Rope technology, Ropes & fibre ropes, wire ropes, nets
- Applies to
- Natural fibre ropes and technical fibre ropes under tension, wire ropes, hybrid ropes where the figure refers to the finished rope. Not to nets and other mesh or sheet assemblies by way of the breaking load of one mesh.
- Related shop areas
- Ropes & fibre ropes, Yacht ropes, Stainless steel wire rope, Nets, Mooring lines
- Not to be confused with
- Individual product breaking loads, splicing instructions or the approval of a load. The manufacturer's information, the applicable standard and the condition of the rope or net remain decisive.
What the breaking load states
The breaking load is the highest force that is measured in a tensile test, or stated as a nominal value, before the test piece breaks. For fibre ropes, DIN EN ISO 2307 specifies how diameter, elongation and breaking force are determined under laboratory conditions. Catalogue values apply to brand-new material.
LIROS determines stated breaking loads linearly to DIN EN ISO 2307, for example for Top-Cruising or D-Pro. The linear figure describes the rope without a typical in-use end termination. An eye, a swaged sleeve or a knot carries a different load.
What force the finished end termination can still take depends on the method. Made according to the manufacturer's instructions, a splice often reaches 90–100 %, depending on rope, diameter and splice type; splices that are too short, considerably less. Knots, U-bolt clips and swage sleeves are other end terminations and often reach considerably less than the linear catalogue value.
What the working load states
The working load is the load permissible in use under the assumed conditions. Internationally, the manufacturer's value is often called the Working Load Limit (WLL). Payload and load capacity are often used synonymously in the trade. SWL (Safe Working Load) is the older designation. The Cordage Institute defines WLL as the minimum breaking force divided by the design factor of the application.
There is no single percentage for all ropes and all applications. Hamburger Tauwerk limits the working load in general use to at most one fifth of the breaking load. This corresponds to the international lower limit of many fibre rope manufacturers and of the Cordage Institute (design factor of at least 5:1). For synthetic fibre ropes, LIROS states an average working load of about 30 % and an upper limit of 50 % of the breaking load. The LIROS values apply to the use described by the manufacturer. They do not replace lifting equipment marking.
Products for lifting loads and for protecting persons are marked separately and carry their own, often printed, WLL. Halyards and sheets as well as mooring lines such as LIROS Porto are as a rule offered with a linear breaking load, not with a WLL.
Design factor in breaking load and working load
The design factor (also called safety factor) is the ratio of breaking load to working load: WLL = MBL / design factor. Internationally the same thing is often called the Design Factor (DF): WLL = MBS / DF. With factor 5, the permissible working load is one fifth of the breaking load, with factor 7 one seventh. Shock load, deflection, ageing and the end termination are not included in this.
Factor 5 and factor 7 belong to different product groups and must not be mixed up. For general fibre rope, the Cordage Institute recommends design factors in the range 5:1 to 12:1, depending on the severity of use and the risk. For normal use Samson states at least 5:1, and 10:1 for climbing lines. Hamburger Tauwerk uses the same factor 5 as guidance for cut-to-length fibre rope and wire rope without a printed WLL. For marked wire rope slings, factor 5 is the utilisation coefficient under DIN EN 13414-1; there the efficiency of the end termination is added on top. For textile lifting slings to DIN EN 1492, the minimum breaking force is seven times the WLL. This applies to marked webbing slings and round slings, not to yacht rope and not to wire rope from the reel. None of these figures applies to lifting or securing persons, unless the relevant PPE or lifting standard expressly provides for it.
| Area | Specification | Source |
|---|---|---|
| Fibre rope, general use / payload | Working load at most 1/5 of the breaking load | Hamburger Tauwerk |
| Wire rope cut to length, general use / payload | Payload at most 1/5 of the breaking load; take the finished end termination into account separately | Hamburger Tauwerk |
| Fibre rope, general use | Design factor typically 5:1 to 12:1 (WLL = MBS / DF) | Cordage Institute CI 1401 |
| Fibre rope, normal use / climbing line | at least 5:1; climbing line 10:1 | Samson Rope |
| LIROS synthetic fibre rope | on average approx. 30 %, at most 50 % of the breaking load | LIROS safety notes |
| Wire rope sling for lifting goods (marked lifting equipment, not cut-to-length rope) | Utilisation coefficient 5, plus the efficiency of the end termination | DIN EN 13414-1 |
| Textile lifting sling (webbing sling, round sling) for lifting goods | Minimum breaking force = 7 × WLL, marked products only | DIN EN 1492-1 / 1492-2 |
| Fall from height, lifting persons | do not derive from the catalogue breaking load | PPE with WLL or minimum breaking force, including DIN EN 1891, DIN EN 361, DIN EN 795, DIN EN 1263-1 |
For design, the figure for the specific rope and the application applies. For cut-to-length rope without a WLL, Hamburger Tauwerk applies the more conservative limit: at most one fifth of the catalogue breaking load. This is at the lower end of the Cordage Institute range and corresponds to Samson (Warning Statement, design factor of at least 5:1 for normal use).
Recommendation on the design factor
For cut-to-length rope without a printed WLL and without personal safety use: at most one fifth of the catalogue breaking load. This corresponds to the payload stated for stainless steel wire rope, for example 7×7 or 7×19, and to the international minimum of many fibre rope manufacturers (design factor 5:1).
Marked webbing slings and round slings are used according to the printed WLL. This already contains the standard requirement of minimum breaking force = 7 × WLL under DIN EN 1492. Yacht rope, hemp rope and cut-to-length wire rope do not fall under this lifting standard.
Shock, knots, tight deflection, wetness, UV or unknown age call for a lower load or replacement of the rope. Sudden forces load a rope far beyond the static load and can reduce its strength unexpectedly sharply.
Fall protection and lifting persons are separate product groups. Only marked PPE or lifting equipment with its own WLL or a specified minimum breaking force is permissible, for example to DIN EN 1891, DIN EN 361, DIN EN 795 or DIN EN 1263-1. Dividing the catalogue breaking load of yacht rope or hemp rope by 5 or 7 does not make it personal protective equipment.
A net is not designed on the breaking load of a yarn or a mesh. The load is distributed over meshes, knots and border rope. For safety nets against falls, DIN EN 1263-1 applies. A universal net is not a fall protection net. The Nature Touch climbing rope and the poly-hemp handrail rope are play and handrail ropes, not PPE.
Breaking load and working load by rope, wire rope, hybrid and net
Fibre rope and wire rope carry tensile load in the rope cross-section. The catalogue breaking load describes this rope. The structure (laid, double braid or hollow braid) is the rope construction and is independent of the fibre name alone. A hybrid rope combines materials; the breaking loads of the components are not added. A net is a mesh product. The breaking load of a mesh is not the load capacity of the net.
Technical fibre ropes
Technical fibre ropes include polyester (PES), polyamide (PA), polypropylene (PP/PPM) and HMPE (Dyneema); they are stated with a linear breaking load to DIN EN ISO 2307, for example laid polyester, all-round rope (polyester cover, PP core), laid PP, LIROS D-Pro or MagSteel D12. Polyamide stretches more than polyester and is usual in mooring lines such as LIROS Porto. HMPE stretches very little and tolerates knots poorly. Aramid and Vectran are further high-modulus fibres. Weathering lowers the breaking load. Without a marked WLL, at most one fifth of the breaking load applies for general use, not the lifting standard for textile slings.
Natural fibre ropes and poly-hemp
Natural fibres such as hemp, sisal and manila are stated with a breaking load for new, dry rope, often in daN. Wetness, rot and UV lower the strength. The catalogue value does not apply to wet or aged natural fibre rope. There is no separate working load percentage for hemp alone. In general use, Hamburger Tauwerk stays at no more than one fifth and at the actual condition of the rope. Poly-hemp (Spleitex) is polypropylene staple fibre with a hemp look. Its breaking load follows synthetic fibre rope, not natural hemp.
Wire ropes
The breaking load of wire rope depends on construction, nominal diameter and material. Usual constructions are 1×19 rigid, 7×7 flexible, 7×19 very flexible and compacted standing rigging wire (Python Compacted Strand). 6×19 with PP core is wire rope with a fibre core; the breaking load is that of the wire rope, not the sum of steel and fibre. A PVC sheath protects but does not carry load.
In addition to the breaking load, Hamburger Tauwerk states a payload of one fifth for cut-to-length wire rope. This is guidance for general use and corresponds to the utilisation coefficient of 5 that DIN EN 13414-1 requires for wire rope slings. For marked slings for lifting goods, the efficiency of the end termination is added on top. U-bolt clips and swage sleeves are such end terminations: they determine what proportion of the rope's breaking load remains usable at the finished eye or swage. The catalogue payload of the cut-to-length rope does not replace this; it is the permissible working load of the rope itself, not the approval of lifting equipment. Wire rope from the reel without sling marking and without a printed WLL is therefore not lifting equipment and must not be used like a tested sling.
Hybrid ropes
Yacht hybrid ropes typically combine a high-strength core with a different cover, for example LIROS Racer Hybrid with a Dyneema core. The catalogue breaking load applies to the finished rope, not as a sum of the material breaking loads. Stiffness, permissible deflection and end termination follow the manufacturer's information. Double braid rope made of two synthetic fibres without a hybrid designation, such as all-round rope, is not a hybrid in this sense: it has a catalogue breaking load like any other fibre rope.
Nets and other sheet assemblies
A net consists of yarn or braided strand, meshes and often a border rope. The breaking load of the yarn or of a single mesh is not the load capacity of the finished net. The load is distributed unevenly over many meshes, knots and the edge. That is why a net is not designed like a rope with working load = breaking load / 5 or / 7. Nets in the shop, such as the universal net 45 mm, are mesh products, not tension ropes. A webbing sling to DIN EN 1492 is a marked lifting accessory with a WLL, not a net and not rope sold by the metre.
Garden, barrier and storage nets are different products from fall protection nets. Safety nets against falls to DIN EN 1263-1 are designed by energy absorption, system class and prescribed rope breaking forces, not by the catalogue breaking load of a decorative or protective net mesh.
Units of breaking load and working load
Catalogues mix daN, kN and kg. 1 daN = 10 N. 1 kN = 100 daN = 1000 N. The weight force of 1 kg is about 9.81 N, so about 0.981 daN. Price lists often treat daN and kg as equal. That is an approximation, not an identity.
Hamburger Tauwerk states hemp breaking loads in daN, for example for laid hemp rope. Stainless steel wire rope breaking loads and payloads are given in kg, for example for 7×7 and in the category stainless steel wire rope by the metre. Check the unit before comparing two figures.
What the catalogue breaking load does not include
The catalogue figure applies to new material in the intended test, mostly linear and dry. It does not include knots, chafing, UV, wetness, dirt, ageing, shock and deflection. Dynamic and static loading, UV, temperature, wetness, contamination, ageing and storage change the values. A non-destructive determination of the current breaking load is not possible.
The end termination determines what proportion of the rope's breaking load remains usable. Details on splices, knots, U-bolt clips and swage sleeves are under Splicing.
Distinguishing breaking load and working load from related terms
- Working stretch
- Elongation of the rope at a specified fraction of the breaking load. Not a load figure. Working stretch
- Minimum breaking force / MBL
- Breaking force specified by the manufacturer or the standard that must not be undercut. In English, Minimum Breaking Load.
- Linear breaking load
- Test value to DIN EN ISO 2307 on fibre rope without a typical in-use end termination. Basis for rating in the catalogue.
- WLL / payload / load capacity
- Permissible working load. Marked on lifting equipment. Often not stated as a WLL for yacht rope. Internationally: Working Load Limit = minimum breaking force / design factor.
- Design factor / safety factor
- Ratio of minimum breaking force to working load. Cordage Institute: typically 5:1 to 12:1 depending on application and risk.
- SWL
- Safe Working Load, older designation for the permissible working load.
- Splice
- End termination that determines what proportion of the rope's breaking load remains usable. It replaces neither the catalogue breaking load nor the permissible working load. Splicing
From our workshop
Customers usually ask us for the catalogue breaking load first and want to work out a “safe load” from it. For cut-to-length rope without a printed WLL we keep to at most one fifth of the breaking load, and we look at the actual condition of the rope, not just the laboratory figure. The mistake we see most often is a knot in a load-bearing end, or an end termination that costs a large share of the breaking load, while the customer still has the full catalogue figure in mind. Where an end needs making up, we splice it in the workshop; see Splicing.
FAQ on breaking load and working load
What is the difference between breaking load and working load?
The breaking load is the force at which the test piece breaks, or the force stated as a nominal value. The working load is the load permissible in use. It is always well below that.
Is working load the same as working stretch?
No. Working load is a force. Working stretch is an elongation. Details are under Working stretch.
How much weight can a rope safely hold?
Far less than its catalogue breaking load. The catalogue figure applies to new material in the laboratory test, mostly linear. In-use conditions, end termination, shock, UV and ageing are below that. The working load keeps the required margin to the breaking load.
Which design factor (safety factor) should I use for rope?
The one for the application and from the manufacturer. For cut-to-length rope without a WLL and without personal safety use: at most one fifth of the catalogue breaking load (design factor 5:1; Cordage Institute, Samson, Hamburger Tauwerk). Marked textile webbing slings: the printed WLL; this contains minimum breaking force = 7 × WLL to DIN EN 1492. Wire rope slings for lifting goods: DIN EN 13414-1 with utilisation coefficient 5. Fall from height or lifting persons: marked PPE or lifting equipment, not the catalogue breaking load divided by 5 or 7.
Is a safety factor of 7 the right value where people are at risk?
No. The factor of seven applies to marked textile lifting slings for lifting goods to DIN EN 1492. Factor 5 applies to steel wire rope slings to DIN EN 13414-1 and as general rope guidance (Cordage Institute, Samson, Hamburger Tauwerk). Both standards exclude the lifting of persons. Where people fall or are lifted, PPE standards with their own WLL or minimum breaking force apply.
Can I treat daN and kilograms as equal?
Only approximately. 1 daN = 10 N. 1 kg of weight force is about 9.81 N. Catalogues often treat daN and kg as equal. Read the stated unit before calculating.
How is working load worked out for fibre rope, wire rope and nets?
It differs by product. Fibre rope and wire rope carry tensile load in the rope cross-section; the working load follows the design factor of the application, for example for laid polyester or 7×7 wire rope. Hybrid ropes such as Racer Hybrid have a catalogue breaking load for the finished rope, not the sum of the materials. A net such as the universal net is a mesh product. The breaking load of a mesh is not the load capacity of the net.
Can I use the breaking load of a net like that of a rope?
No. The breaking load of a yarn or mesh is not the load capacity of the finished net. Fall protection nets to DIN EN 1263-1 are designed by energy absorption and system class.
Does a splice reduce the strength of a rope?
The splice changes the usable breaking load of the end termination, not the definition of the rope's breaking load. Made according to the manufacturer's instructions, a splice often reaches 90–100 %, depending on rope, diameter and splice type; splices that are too short, considerably less. Knots as a rule retain considerably less. Details are on the page Splicing.
Further reading on breaking load and working load
- Splicing
- Rope construction
- Working stretch
- Technical fibre ropes
- High-modulus fibres
- Natural fibres
- Ropes & fibre ropes
- Hemp rope / natural hemp, laid hemp rope
- Dyneema / HMPE, LIROS D-Pro
- LIROS Top-Cruising, LIROS Porto
- Stainless steel wire rope by the metre, 7×7
- Wire rope clip and thimble, Swage sleeves
- Nets / protective nets, Universal net 45 mm
- Halyards and sheets, Mooring lines and anchor lines
- Climbing rope, Handrail rope
- LIROS
Sources and status on breaking load and working load
Last reviewed on .
- DIN EN ISO 2307: Fibre ropes: determination of physical and mechanical properties, including breaking force. International test standard; does not specify a working load.
- Cordage Institute: CI 1401 Safer Use of Fiber Rope. Minimum Breaking Strength (MBS), Working Load Limit (WLL), Design Factor (DF). WLL = MBS / DF. For general use typically DF 5:1 to 12:1, depending on severity of use and risk; life-saving ropes and specially designed ropes excluded.
- Samson Rope: Warning Statement. WLL = MBS / Safety Factor. For normal use at least 5:1 (approx. 20 % of the breaking force of new, correctly spliced rope); for climbing lines 10:1. Shock, sustained load and danger to persons call for higher factors.
- LIROS: Technical information. Breaking loads linear to DIN EN ISO 2307. Working stretch at 30 % of the linear breaking load. Average working load approx. 30 %, maximum working load 50 %. A knot reduces the breaking load by up to 70 %, depending on material and knot. Products for lifting and for personal safety are marked separately.
- DIN EN 13414-1: Wire rope slings: safety. Utilisation coefficient 5 for general lifting of goods, not for persons.
- DIN EN 1492-1 and DIN EN 1492-2: Textile lifting slings (webbing slings, round slings). Minimum breaking force seven times the WLL. Not for lifting persons. Does not apply to nets made of crossed straps.
- DIN EN 1263-1: Safety nets. Energy absorption and rope breaking forces, not the simple rope working load.
- DIN EN 1891, DIN EN 361, DIN EN 795: Ropes and components of personal fall protection equipment. Their own minimum breaking forces or WLL.
- Hamburger Tauwerk: stainless steel wire rope, payload as one fifth of the stated breaking load, e.g. 7×7. Hemp rope, breaking load in daN, e.g. laid hemp rope. Guidance for cut-to-length rope without a WLL: at most one fifth of the catalogue breaking load.
- Further reading (background term WLL): Wikipedia (German): Working Load Limit; Cordage Institute CI 1401 and the Samson Warning Statement above remain the authority.
This page is published by Hamburger Tauwerk Fabrik GmbH & Co. KG, Hamburg. The information is provided for orientation and general understanding. It is not a binding design specification and not an approval for any application or for safety purposes. The current product data sheet, the manufacturer's information, the applicable standard and the condition of the rope remain decisive.